diff --git a/alarm-01.tn.esss.lu.se/RGTCS.xml b/alarm-01.tn.esss.lu.se/RGTCS.xml index d087e55ad0f90c25612f58b30ccbfdeedb86921b..0aacc696eed4dc26e157951a3f1e69bee6d264f3 100644 --- a/alarm-01.tn.esss.lu.se/RGTCS.xml +++ b/alarm-01.tn.esss.lu.se/RGTCS.xml @@ -241,148 +241,64 @@ <annunciating>false</annunciating> </pv> <pv name="Tgt-RGT1040:Proc-P-205:ThermistorFault"> - <description>P 205 Pump Thermistor Alarm</description> + <description>P 205 Pump Thermistor alarm</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> - </pv> - <pv name="Tgt-RGT1040:Proc-P-205:Overheated"> - <description>P 205 Pump Drive overheat</description> - <latching>false</latching> - <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-P-205:Fault"> <description>P 205 Pump Drive fault</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-P-205:DiscrepancyAlarm"> <description>P 205 Pump Setpoint discrepancy</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> - </pv> - <pv name="Tgt-RGT1040:Proc-P-205:ModuleDiagError"> - <description>P 205 Pump Profinet error</description> - <latching>false</latching> - <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-P-205:SSTriggered"> <description>P 205 Pump Safe state triggered</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-P-205:DriveContactorOff"> <description>P 205 Pump Drive contactor OFF</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-P-205:MotorDisconnectorOff"> <description>P 205 Pump Motor disconnector switch turned OFF</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-P-255:ThermistorFault"> - <description>P 255 Pump Thermistor Alarm</description> + <description>P 255 Pump Thermistor alarm</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> - </pv> - <pv name="Tgt-RGT1040:Proc-P-255:Overheated"> - <description>P 255 Pump Drive overheat</description> - <latching>false</latching> - <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-P-255:Fault"> <description>P 255 Pump Drive fault</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-P-255:DiscrepancyAlarm"> <description>P 255 Pump Setpoint discrepancy</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> - </pv> - <pv name="Tgt-RGT1040:Proc-P-255:ModuleDiagError"> - <description>P 255 Pump Profinet error</description> - <latching>false</latching> - <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-P-255:SSTriggered"> <description>P 255 Pump Safe state triggered</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-P-255:DriveContactorOff"> <description>P 255 Pump Drive contactor OFF</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-P-255:MotorDisconnectorOff"> <description>P 255 Pump Motor disconnector switch turned OFF</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-PT-137:Overrange"> <description>PT 137 Transmitter Overrange</description> @@ -919,203 +835,105 @@ <latching>false</latching> <annunciating>false</annunciating> </pv> - <pv name="Tgt-RGT1040:Proc-V-102:SPLimitActive"> - <description>V 102 Drive Limit of setpoint reached</description> + <pv name="Tgt-RGT1040:Proc-V-102:Alarm"> + <description>V 102 G120C Drive Alarm signal</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> - <pv name="Tgt-RGT1040:Proc-V-102:Alarm"> - <description>V 102 Drive Alarm</description> + <pv name="Tgt-RGT1040:Proc-V-102:Warning"> + <description>V 102 G120C Drive Warning signal</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> - <pv name="Tgt-RGT1040:Proc-V-102:Overheated"> - <description>V 102 Drive overheated/thermistor fault/</description> + <pv name="Tgt-RGT1040:Proc-V-102:DiscrepancyAlarm"> + <description>V 102 G120C Drive Setpoint discrepancy</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> - <pv name="Tgt-RGT1040:Proc-V-102:Fault"> - <description>V 102 Drive fault</description> + <pv name="Tgt-RGT1040:Proc-V-102:TorqueLimit"> + <description>V 102 G120C Drive Torque limit reached</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> - <pv name="Tgt-RGT1040:Proc-V-102:DiscrepancyAlarm"> - <description>V 102 Drive Setpoint discrepancy</description> + <pv name="Tgt-RGT1040:Proc-V-102:DriveOverLoad"> + <description>V 102 G120C Drive Overload</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> - <pv name="Tgt-RGT1040:Proc-V-102:Warning"> - <description>V 102 Drive warning present</description> + <pv name="Tgt-RGT1040:Proc-V-102:SPLimitActive"> + <description>V 102 G120C Drive Setpoint limit reached</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-V-102:SSTriggered"> - <description>V 102 Drive Safe state triggered</description> + <description>V 102 G120C Drive Safe state triggered</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-V-102:DriveContactorOff"> - <description>V 102 Drive contactor OFF</description> + <description>V 102 G120C Drive Drive contactor OFF</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-V-102:MotorDisconnectorOff"> - <description>V 102 Motor disconnector switch turned OFF</description> - <latching>false</latching> - <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> - </pv> - <pv name="Tgt-RGT1040:Proc-V-102:TorqueLimit"> - <description>V 102 Drive torque limit reached</description> + <description>V 102 G120C Drive Motor disconnector switch turned OFF</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> - <pv name="Tgt-RGT1040:Proc-V-102:DriveOverload"> - <description>V 102 Drive overload alarm</description> + <pv name="Tgt-RGT1040:Proc-V-102:ThermistorFault"> + <description>V 102 G120C Drive Thermistor alarm</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> - <pv name="Tgt-RGT1040:Proc-V-152:SPLimitActive"> - <description>V 152 Drive Limit of setpoint reached</description> + <pv name="Tgt-RGT1040:Proc-V-152:Alarm"> + <description>V 152 G120C Drive Alarm signal</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> - <pv name="Tgt-RGT1040:Proc-V-152:Alarm"> - <description>V 152 Drive Alarm</description> + <pv name="Tgt-RGT1040:Proc-V-152:Warning"> + <description>V 152 G120C Drive Warning signal</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> - <pv name="Tgt-RGT1040:Proc-V-152:Overheated"> - <description>V 152 Drive overheated/thermistor fault/</description> + <pv name="Tgt-RGT1040:Proc-V-152:DiscrepancyAlarm"> + <description>V 152 G120C Drive Setpoint discrepancy</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> - <pv name="Tgt-RGT1040:Proc-V-152:Fault"> - <description>V 152 Drive fault</description> + <pv name="Tgt-RGT1040:Proc-V-152:TorqueLimit"> + <description>V 152 G120C Drive Torque limit reached</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> - <pv name="Tgt-RGT1040:Proc-V-152:DiscrepancyAlarm"> - <description>V 152 Drive Setpoint discrepancy</description> + <pv name="Tgt-RGT1040:Proc-V-152:DriveOverLoad"> + <description>V 152 G120C Drive Overload</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> - <pv name="Tgt-RGT1040:Proc-V-152:Warning"> - <description>V 152 Drive warning present</description> + <pv name="Tgt-RGT1040:Proc-V-152:SPLimitActive"> + <description>V 152 G120C Drive Setpoint limit reached</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-V-152:SSTriggered"> - <description>V 152 Drive Safe state triggered</description> + <description>V 152 G120C Drive Safe state triggered</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-V-152:DriveContactorOff"> - <description>V 152 Drive contactor OFF</description> + <description>V 152 G120C Drive Drive contactor OFF</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-V-152:MotorDisconnectorOff"> - <description>V 152 Motor disconnector switch turned OFF</description> - <latching>false</latching> - <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> - </pv> - <pv name="Tgt-RGT1040:Proc-V-152:TorqueLimit"> - <description>V 152 Drive torque limit reached</description> + <description>V 152 G120C Drive Motor disconnector switch turned OFF</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> - <pv name="Tgt-RGT1040:Proc-V-152:DriveOverload"> - <description>V 152 Drive overload alarm</description> + <pv name="Tgt-RGT1040:Proc-V-152:ThermistorFault"> + <description>V 152 G120C Drive Thermistor alarm</description> <latching>false</latching> <annunciating>false</annunciating> - <guidance> - <title>Details</title> - <details>More details on the pump faceplate</details> - </guidance> </pv> <pv name="Tgt-RGT1040:Proc-FICA-105:ContDeviceInMan"> <description>FICA 105 PID controller Controlled device in manual mode</description> @@ -1127,6 +945,26 @@ <latching>false</latching> <annunciating>false</annunciating> </pv> + <pv name="Tgt-RGT1040:Proc-FICA-105:ProcHiHi"> + <description>FICA 105 PID controller Error HIGH HIGH alarm active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-FICA-105:ProcHi"> + <description>FICA 105 PID controller Error HIGH warning active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-FICA-105:ProcLo"> + <description>FICA 105 PID controller Error LOW warning active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-FICA-105:ProcLoLo"> + <description>FICA 105 PID controller Error LOW LOW alarm active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> <pv name="Tgt-RGT1040:Proc-TICA-116:ContDeviceIncInMan"> <description>TICA 116 On Off controller Pressure increasing controlled device in manual mode</description> <latching>false</latching> @@ -1137,6 +975,31 @@ <latching>false</latching> <annunciating>false</annunciating> </pv> + <pv name="Tgt-RGT1040:Proc-TICA-116:SSTriggered"> + <description>TICA 116 On Off controller Safe state triggered</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-TICA-116:ProcHiHi"> + <description>TICA 116 On Off controller Error HIGH HIGH alarm active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-TICA-116:ProcHi"> + <description>TICA 116 On Off controller Error HIGH warning active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-TICA-116:ProcLo"> + <description>TICA 116 On Off controller Error LOW warning active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-TICA-116:ProcLoLo"> + <description>TICA 116 On Off controller Error LOW LOW alarm active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> <pv name="Tgt-RGT1040:Proc-PICA-137:ContDeviceIncInMan"> <description>PICA 137 On Off controller Pressure increasing controlled device in manual mode</description> <latching>false</latching> @@ -1147,6 +1010,31 @@ <latching>false</latching> <annunciating>false</annunciating> </pv> + <pv name="Tgt-RGT1040:Proc-PICA-137:SSTriggered"> + <description>PICA 137 On Off controller Safe state triggered</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-PICA-137:ProcHiHi"> + <description>PICA 137 On Off controller Error HIGH HIGH alarm active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-PICA-137:ProcHi"> + <description>PICA 137 On Off controller Error HIGH warning active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-PICA-137:ProcLo"> + <description>PICA 137 On Off controller Error LOW warning active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-PICA-137:ProcLoLo"> + <description>PICA 137 On Off controller Error LOW LOW alarm active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> <pv name="Tgt-RGT1040:Proc-AIC-193:ContDeviceIncInMan"> <description>AIC 193 On Off controller Pressure increasing controlled device in manual mode</description> <latching>false</latching> @@ -1157,6 +1045,31 @@ <latching>false</latching> <annunciating>false</annunciating> </pv> + <pv name="Tgt-RGT1040:Proc-AIC-193:SSTriggered"> + <description>AIC 193 On Off controller Safe state triggered</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-AIC-193:ProcHiHi"> + <description>AIC 193 On Off controller Error HIGH HIGH alarm active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-AIC-193:ProcHi"> + <description>AIC 193 On Off controller Error HIGH warning active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-AIC-193:ProcLo"> + <description>AIC 193 On Off controller Error LOW warning active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-AIC-193:ProcLoLo"> + <description>AIC 193 On Off controller Error LOW LOW alarm active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> <pv name="Tgt-RGT1040:Proc-LICA-131:ContDeviceIncInMan"> <description>LICA 131 On Off controller Pressure increasing controlled device in manual mode</description> <latching>false</latching> @@ -1167,6 +1080,31 @@ <latching>false</latching> <annunciating>false</annunciating> </pv> + <pv name="Tgt-RGT1040:Proc-LICA-131:SSTriggered"> + <description>LICA 131 On Off controller Safe state triggered</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-LICA-131:ProcHiHi"> + <description>LICA 131 On Off controller Error HIGH HIGH alarm active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-LICA-131:ProcHi"> + <description>LICA 131 On Off controller Error HIGH warning active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-LICA-131:ProcLo"> + <description>LICA 131 On Off controller Error LOW warning active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-LICA-131:ProcLoLo"> + <description>LICA 131 On Off controller Error LOW LOW alarm active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> <pv name="Tgt-RGT1040:Proc-LT-131:Overrange"> <description>LT 131 Transmitter Overrange</description> <latching>false</latching> @@ -1377,6 +1315,26 @@ <latching>false</latching> <annunciating>false</annunciating> </pv> + <pv name="Tgt-RGT1040:Proc-FICA-155:ProcHiHi"> + <description>FICA 155 PID controller Error HIGH HIGH alarm active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-FICA-155:ProcHi"> + <description>FICA 155 PID controller Error HIGH warning active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-FICA-155:ProcLo"> + <description>FICA 155 PID controller Error LOW warning active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-FICA-155:ProcLoLo"> + <description>FICA 155 PID controller Error LOW LOW alarm active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> <pv name="Tgt-RGT1040:Proc-LICA-151:ContDeviceIncInMan"> <description>LICA 151 On Off controller Pressure increasing controlled device in manual mode</description> <latching>false</latching> @@ -1387,6 +1345,31 @@ <latching>false</latching> <annunciating>false</annunciating> </pv> + <pv name="Tgt-RGT1040:Proc-LICA-151:SSTriggered"> + <description>LICA 151 On Off controller Safe state triggered</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-LICA-151:ProcHiHi"> + <description>LICA 151 On Off controller Error HIGH HIGH alarm active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-LICA-151:ProcHi"> + <description>LICA 151 On Off controller Error HIGH warning active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-LICA-151:ProcLo"> + <description>LICA 151 On Off controller Error LOW warning active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> + <pv name="Tgt-RGT1040:Proc-LICA-151:ProcLoLo"> + <description>LICA 151 On Off controller Error LOW LOW alarm active</description> + <latching>false</latching> + <annunciating>false</annunciating> + </pv> <pv name="Tgt-RGT1040:Proc-TT-167:Overrange"> <description>TT 167 Transmitter Overrange</description> <latching>false</latching> @@ -1467,33 +1450,33 @@ <latching>false</latching> <annunciating>false</annunciating> </pv> - <pv name="Tgt-RGT1040:Proc-W-110:DeviceFault"> - <description>W 110 Heater alarm</description> + <pv name="Tgt-RGT1040:Proc-W-110:DiscrepancyAlarm"> + <description>W 110 Heater Setpoint discrepancy</description> <latching>false</latching> <annunciating>false</annunciating> </pv> - <pv name="Tgt-RGT1040:Proc-W-110:DiscrepancyAlarm"> - <description>W 110 Analyzer could not turn on/off</description> + <pv name="Tgt-RGT1040:Proc-W-110:DeviceFault"> + <description>W 110 Heater Fault signal</description> <latching>false</latching> <annunciating>false</annunciating> </pv> <pv name="Tgt-RGT1040:Proc-W-110:SSTriggered"> - <description>W 110 Safe state triggered</description> + <description>W 110 Heater Safe state triggered</description> <latching>false</latching> <annunciating>false</annunciating> </pv> - <pv name="Tgt-RGT1040:Proc-W-124:DeviceFault"> - <description>W 124 Heater alarm</description> + <pv name="Tgt-RGT1040:Proc-W-124:DiscrepancyAlarm"> + <description>W 124 Heater Setpoint discrepancy</description> <latching>false</latching> <annunciating>false</annunciating> </pv> - <pv name="Tgt-RGT1040:Proc-W-124:DiscrepancyAlarm"> - <description>W 124 Analyzer could not turn on/off</description> + <pv name="Tgt-RGT1040:Proc-W-124:DeviceFault"> + <description>W 124 Heater Fault signal</description> <latching>false</latching> <annunciating>false</annunciating> </pv> <pv name="Tgt-RGT1040:Proc-W-124:SSTriggered"> - <description>W 124 Safe state triggered</description> + <description>W 124 Heater Safe state triggered</description> <latching>false</latching> <annunciating>false</annunciating> </pv> @@ -1593,32 +1576,32 @@ <annunciating>false</annunciating> </pv> <pv name="Tgt-RGT1040:Proc-AIT-190:DetectorAlarm"> - <description>AIT 190 Detector has alarm</description> + <description>AIT 190 Gas analyser Alarm signal</description> <latching>false</latching> <annunciating>false</annunciating> </pv> <pv name="Tgt-RGT1040:Proc-AIT-190:CabinetAlarm"> - <description>AIT 190 Gas Analyzer Cabinet alarm</description> + <description>AIT 190 Gas analyser Cabinet alarm</description> <latching>false</latching> <annunciating>false</annunciating> </pv> <pv name="Tgt-RGT1040:Proc-AIT-190:DiscrepancyAlarm"> - <description>AIT 190 Analyzer could not turn on/off</description> + <description>AIT 190 Gas analyser Setpoint discrepancy</description> <latching>false</latching> <annunciating>false</annunciating> </pv> <pv name="Tgt-RGT1040:Proc-AIT-190:PCConnAlarm"> - <description>AIT 190 Connection alarm with PC</description> + <description>AIT 190 Gas analyser Connection to PC lost</description> <latching>false</latching> <annunciating>false</annunciating> </pv> - <pv name="Tgt-RGT1040:Proc-AIT-190:SSTriggered"> - <description>AIT 190 Safe state triggered</description> + <pv name="Tgt-RGT1040:Proc-AIT-190:BSQ"> + <description>AIT 190 Gas analyser Bas signal quality</description> <latching>false</latching> <annunciating>false</annunciating> </pv> - <pv name="Tgt-RGT1040:Proc-AIT-190:BSQ"> - <description>AIT 190 Bad Signal Quality</description> + <pv name="Tgt-RGT1040:Proc-AIT-190:SSTriggered"> + <description>AIT 190 Gas analyser Safe state triggered</description> <latching>false</latching> <annunciating>false</annunciating> </pv>