From 1a5f75b1ed7926ab09df348de131c3bd2f2d68b1 Mon Sep 17 00:00:00 2001
From: =?UTF-8?q?Kriszti=C3=A1n=20L=C3=B6ki?= <krisztian.loki@ess.eu>
Date: Fri, 18 Sep 2020 16:08:45 +0200
Subject: [PATCH] Updated warning and error codes

---
 NON-APPROVED/COMMON/DEVICES/vacuum/vpg/error.py   | 6 ------
 NON-APPROVED/COMMON/DEVICES/vacuum/vpg/warning.py | 5 +++++
 2 files changed, 5 insertions(+), 6 deletions(-)

diff --git a/NON-APPROVED/COMMON/DEVICES/vacuum/vpg/error.py b/NON-APPROVED/COMMON/DEVICES/vacuum/vpg/error.py
index 049ead6d..eb95bce5 100644
--- a/NON-APPROVED/COMMON/DEVICES/vacuum/vpg/error.py
+++ b/NON-APPROVED/COMMON/DEVICES/vacuum/vpg/error.py
@@ -19,13 +19,7 @@ if PVUtil.getLong(pvs[0]):
                  90 : "Turbo-Pumps Not Available",
                  89 : "Max Auto-Restart",
                  88 : "Back-Up Primary Pumping System Error",
-                 85 : "VPSU-00020 24VDC Power Supply Overload",
-                 84 : "VPSU-00020 24VDC Power Supply Tripped",
                  83 : "VPSU-00020 400VAC 3-Phases Power Supply Tripped",
-                 82 : "VPSU-00010 24VDC Power Supply Overload",
-                 81 : "VPSU-00010 24VDC Power Supply Tripped",
-                 80 : "VPSU-00010 400VAC 3-Phases Power Supply Tripped",
-
                  15 : "Mode Selection Error - Vacuum Sector Vented",
                  14 : "Mode Selection Error - Vacuum Sector Under Vacuum",
                  13 : "Primary Pumping System: Rescue Primary System is Off",
diff --git a/NON-APPROVED/COMMON/DEVICES/vacuum/vpg/warning.py b/NON-APPROVED/COMMON/DEVICES/vacuum/vpg/warning.py
index 64df4ea7..030cba31 100644
--- a/NON-APPROVED/COMMON/DEVICES/vacuum/vpg/warning.py
+++ b/NON-APPROVED/COMMON/DEVICES/vacuum/vpg/warning.py
@@ -18,6 +18,11 @@ if PVUtil.getLong(pvs[0]):
                  11 : "Atmospheric & Vacuum Starting are Enabled",
                  10 : "No Starting Enabled",
                  9 : "Atmospheric Starting is Enabled",
+                 8 : "VPSU-0020 24VDC Power Supply Overload",
+                 7 : "VPSU-0020 24VDC Power Supply Tripped",
+                 6 : "VPSU-0010 24VDC Power Supply Overload",
+                 5 : "VPSU-0010 24VDC Power Supply Tripped",
+                 4 : "VPSU-0010 400VAC 3-Phases Power Supply Tripped",
                  3 : "Automatic Restart On-going",
                  2 : "All Pumping Systems Locked - Starting Not Possible",
                  1 : "No Mode Selected",
-- 
GitLab