  • accop/beast-config
  • alarm-server/alarm-server-config
  • rafaelmontano/beast-config
  • waynelewis/beast-config
  • krisztianloki/beast-config
  • miklosboros/beast-config
  • cryo/beast-config
  • pernilsson2/beast-config
  • andersharrisson/alarm-server-config
  • artempetrushenko/beast-config
  • gabrielfedel/beast-config
  • marcmunoz/beast-config
  • loranthorvath/alarm-server-config-thcslrnthrvth-1115
  • saeedhaghtalab/beast-config
  • antonisimelio/alarm-server-config
  • alfiorizzo/beast-config
  • danielecosco/alarm-server-config
  • laispessine/alarm-server-config
  • martinek/alarm-server-config
  • adalbertofontoura/alarm-server-config
  • SRF_Section/control-room-projects/alarm-server-config
  • dawiddwojewski/alarm-server-config
  • emilioasensiconejero/alarm-server-config
  • balazsmolnar/alarm-server-config
  • lucaporzio/alarm-server-config
  • attilahorvath/alarm-server-config
  • aminhosseini/alarm-server-config
  • domagaladominik/alarm-server-config
  • lucianocarneiro/alarm-server-config
  • gabrielfedel/alarm-server-config
  • balintepinger/alarm-server-config
  • dennishasselgren/alarm-server-config
  • haraldligander/alarm-server-config
  • stefanopavinato/alarm-server-config
  • wojciechbinczyk/alarm-server-config
  • markuskristensson/alarm-server-config
  • andrebengtsson/alarm-server-config
  • mateusznabywaniec/alarm-server-config
  • joricklochet/alarm-server-config-mrcs
  • joricklochet/alarm-server-config-tiwccs
  • joricklochet/alarm-server-config-tswcs
  • josecardoso/alarm-server-config
  • carlosneto/alarm-server-config
43 results
Show changes
Commits on Source (245)
Showing
with 65746 additions and 19883 deletions
<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<config name="ACCP">
<config name="ACCP">
<component name="ACCP Adsorber">
<component name="ACCP 20K Adsorber">
<pv name="CrS-ACCP:CRYO-TT-31401:AH">
<description>20K Adsorber inlet temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -13,7 +13,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-A-31450:Sd">
<description>20K Adsorber general shutdown</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -27,7 +27,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31401:AHH">
<description>20K Adsorber inlet temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -36,7 +36,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31490:AH">
<description>20K adsorber outlet pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -45,7 +45,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31490:AL">
<description>20K adsorber outlet pressure low &lt;(0.90*HP)</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -54,7 +54,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31490:ALL">
<description>20K adsorber outlet pressure too low &lt;(0.70*HP)</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -63,7 +63,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31452:AH">
<description>20K Adsorber outlet temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -72,7 +72,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31452:AL">
<description>20K Adsorber outlet temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -81,7 +81,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TS-314501:Aval">
<description>20K Adsorber temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -90,7 +90,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-A-31450:WrnSta004">
<description>20K Adsorber: Exceeding of maximum allowed adsorption time</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -99,7 +99,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31491:AH">
<description>20K regeneration skid inlet temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -108,7 +108,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31491:AL">
<description>20K regeneration skid inlet temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -117,7 +117,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31491:AHH">
<description>20K regeneration skid inlet temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -126,7 +126,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31491:ALL">
<description>20K regeneration skid inlet temperature too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -135,7 +135,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-A-31450:MsgUAH31992">
<description>Closed HV-31992</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -144,7 +144,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-A-31450:MsgUAH31993">
<description>Closed HV-31993</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -153,7 +153,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-A-31450:MsgUAH31994">
<description>Closed HV-31994</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -162,7 +162,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-A-31450:MsgUAL31992">
<description>HV-31992 is open</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -171,7 +171,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-A-31450:MsgUAL31993">
<description>HV-31993 is open</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -180,7 +180,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-A-31450:MsgUAL31994">
<description>HV-31994 is open</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -189,7 +189,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-A-31450:RegSdFuse">
<description>Sd, Fuse fault</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -198,7 +198,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-A-31450:RegSdEMSTP">
<description>Sd, EmStp not ok</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -209,7 +209,7 @@
<component name="ACCP 80K Adsorber A">
<pv name="CrS-ACCP:CRYO-TT-31210A:AHHH">
<description>80K adsorber A high inlet temperature trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -218,7 +218,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31210A:AH">
<description>80K adsorber A inlet temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -227,7 +227,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31210A:AHH">
<description>80K adsorber A inlet temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -236,7 +236,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31220:AH">
<description>80K adsorber A pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -245,7 +245,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31220:AL">
<description>80K adsorber A pressure low P &lt; (0.9*HP)</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -254,7 +254,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31220:ALL">
<description>80K adsorber A pressure too low P &lt; (0.7*HP)</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -263,7 +263,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31480A:AH">
<description>80K Adsorber A-31220A Skid inlet temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -272,7 +272,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31480A:AL">
<description>80K Adsorber A-31220A Skid inlet temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -281,7 +281,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31480A:AHH">
<description>80K Adsorber A-31220A Skid inlet temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -290,7 +290,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31480A:ALL">
<description>80K Adsorber A-31220A Skid inlet temperature too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -299,7 +299,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-A-31220A:WrnSta004">
<description>80K Adsorber A: Exceeding of maximum allowed adsorption time</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -308,7 +308,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-A-31220A:Sd">
<description>80K Adsorber A: Shutdown of adsorption mode of adsorber A</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -317,7 +317,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-A-31220A:RegSd">
<description>80K Adsorber A: Shutdown of regeneration mode of adsorber A</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -328,7 +328,7 @@
<component name="ACCP 80K Adsorber B">
<pv name="CrS-ACCP:CRYO-TT-31210B:AHHH">
<description>80K adsorber B high inlet temperature trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -337,7 +337,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31210B:AH">
<description>80K adsorber B inlet temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -346,7 +346,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31210B:AHH">
<description>80K adsorber B inlet temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -355,7 +355,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31221:AH">
<description>80K adsorber B pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -364,7 +364,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31221:AL">
<description>80K adsorber B pressure low P &lt; (0.9*HP)</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -373,7 +373,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31221:ALL">
<description>80K adsorber B pressure too low P &lt; (0.7*HP)</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -382,7 +382,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31480B:AH">
<description>80K Adsorber B-31220B Skid inlet temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -391,7 +391,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31480B:AL">
<description>80K Adsorber B-31220B Skid inlet temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -400,7 +400,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31480B:AHH">
<description>80K Adsorber B-31220B Skid inlet temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -409,7 +409,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31480B:ALL">
<description>80K Adsorber B-31220B Skid inlet temperature too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -418,7 +418,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-A-31220B:WrnSta004">
<description>80K Adsorber B: Exceeding of maximum allowed adsorption time</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -427,7 +427,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31483:AH">
<description>80K Regeneration Heater Outlet pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -436,7 +436,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TS-31485:Aval">
<description>80K Regeneration Heater temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -445,7 +445,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-A-31220:RegSdEMSTP">
<description>Sd, EmStp not ok</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -454,7 +454,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-A-31220:RegSdFuse">
<description>Sd, Fuse fault</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -467,7 +467,7 @@
<component name="ACCP Turbine 1 (T-31130)">
<pv name="CrS-ACCP:CRYO-TStr-311x0:SdErrT31130">
<description>Sd Turbine 1 (T-31130)</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -481,7 +481,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31130:ALL">
<description>Turbine string T-31130 inlet pressure too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -490,7 +490,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31131:AH">
<description>Turbine T-31130 break circuit temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -499,7 +499,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31131:AHH">
<description>Turbine T-31130 break circuit temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -508,7 +508,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31131:ALL">
<description>Turbine T-31130 low speed trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -517,7 +517,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31131:AHH">
<description>Turbine T-31130 overspeed trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -526,7 +526,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-AS-31131:Aval">
<description>Turbine T-31130 overspeed trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -535,7 +535,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31130:AL">
<description>Warning: turbine T-31130 inlet temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -544,7 +544,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31131:AL">
<description>Warning: turbine T-31130 low speed</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -553,7 +553,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31131:AH">
<description>Warning: turbine T-31130 overspeed</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -562,7 +562,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-T-31130:SdPrsRatio">
<description>T-31130 pressure ratio high </description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -571,7 +571,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TStr-311x0:SdHWS">
<description>T-31130 pressure ratio too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -582,7 +582,7 @@
<component name="ACCP Turbine 2 (T-31150)">
<pv name="CrS-ACCP:CRYO-TStr-311x0:SdErrT31150">
<description></description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -596,7 +596,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31151:AH">
<description>Turbine T-31150 break circuit temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -605,7 +605,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31151:AHH">
<description>Turbine T-31150 break circuit temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -614,7 +614,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31150:ALL">
<description>Turbine T-31150 inlet pressure too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -623,7 +623,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31151:ALL">
<description>Turbine T-31150 low speed trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -632,7 +632,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31155:AL">
<description>Turbine T-31150 outlet temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -641,7 +641,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31155:ALL">
<description>Turbine T-31150 outlet temperature too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -650,7 +650,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31151:AHH">
<description>Turbine T-31150 overspeed trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -659,7 +659,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31150:AL">
<description>Warning: turbine T-31150 inlet temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -668,7 +668,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31151:AL">
<description>Warning: turbine T-31150 low speed</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -677,7 +677,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31151:AH">
<description>Warning: turbine T-31150 overspeed</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -686,7 +686,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-T-31150:SdPrsRatio">
<description>T-31150 pressure ratio high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -697,7 +697,7 @@
<component name="ACCP Turbine 3 (T-31330)">
<pv name="CrS-ACCP:CRYO-TStr-313x0:SdErrT31330">
<description></description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -711,7 +711,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31331:AH">
<description>Turbine T-31330 break circuit temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -720,7 +720,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31331:AHH">
<description>Turbine T-31330 break circuit temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -729,7 +729,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31330:ALL">
<description>Turbine T-31330 inlet pressure too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -738,7 +738,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31331:ALL">
<description>Turbine T-31330 low speed trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -747,7 +747,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31355:AL">
<description>Turbine T-31330 outlet temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -756,7 +756,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31355:ALL">
<description>Turbine T-31330 outlet temperature too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -765,7 +765,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31331:AHH">
<description>Turbine T-31330 overspeed trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -774,7 +774,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-AS-31331:Aval">
<description>Turbine T-31330 overspeed trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -783,7 +783,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31330:AL">
<description>Warning: turbine T-31330 inlet temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -792,7 +792,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31331:AL">
<description>Warning: turbine T-31330 low speed</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -801,7 +801,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31331:AH">
<description>Warning: turbine T-31330 overspeed</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -810,7 +810,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TStr-313x0:SdHWS">
<description>T-31330 pressure ratio too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -819,7 +819,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-T-31330:SdPrsRatio">
<description>T-31330 pressure ratio high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -830,7 +830,7 @@
<component name="ACCP Turbine 4 (T-31530)">
<pv name="CrS-ACCP:CRYO-TStr-315x0:SdErrT31530">
<description></description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -844,7 +844,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31531:AH">
<description>Turbine T-31530 break circuit temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -853,7 +853,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31531:AHH">
<description>Turbine T-31530 break circuit temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -862,7 +862,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31530:ALL">
<description>Turbine T-31530 inlet pressure too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -871,7 +871,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31531:ALL">
<description>Turbine T-31530 low speed trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -880,7 +880,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31531:AHH">
<description>Turbine T-31530 overspeed trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -889,7 +889,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-AS-31531:Aval">
<description>Turbine T-31530 overspeed trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -898,7 +898,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31530:AL">
<description>Warning: turbine T-31530 inlet temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -907,7 +907,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31531:AL">
<description>Warning: turbine T-31530 low speed</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -916,7 +916,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31531:AH">
<description>Warning: turbine T-31530 overspeed</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -925,7 +925,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TStr-315x0:SdHWS">
<description>T-31530 pressure ratio too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -934,7 +934,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-T-31530:SdPrsRatio">
<description>T-31530 pressure ratio high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -945,7 +945,7 @@
<component name="ACCP Turbine 5 (T-31550)">
<pv name="CrS-ACCP:CRYO-TStr-315x0:SdErrT31550">
<description></description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -959,7 +959,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31551:AH">
<description>Turbine T-31550 break circuit temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -968,7 +968,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31551:AHH">
<description>Turbine T-31550 break circuit temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -977,7 +977,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31550:ALL">
<description>Turbine T-31550 inlet pressure too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -986,7 +986,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31551:ALL">
<description>Turbine T-31550 low speed trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -995,7 +995,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31555:AL">
<description>Turbine T-31550 outlet pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1004,7 +1004,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31555:ALL">
<description>Turbine T-31550 outlet pressure too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1013,7 +1013,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31555:AL">
<description>Turbine T-31550 outlet temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1022,7 +1022,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31555:ALL">
<description>Turbine T-31550 outlet temperature too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1031,7 +1031,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31551:AHH">
<description>Turbine T-31550 overspeed trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1040,7 +1040,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-T-31550:SdPrsRatio">
<description>T-31550 pressure ratio high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1049,7 +1049,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31550:AL">
<description>Warning: turbine T-31550 inlet temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1058,7 +1058,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31551:AL">
<description>Warning: turbine T-31550 low speed</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1067,7 +1067,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31551:AH">
<description>Warning: turbine T-31550 overspeed</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1078,7 +1078,7 @@
<component name="ACCP Turbine 6 (T-31730)">
<pv name="CrS-ACCP:CRYO-TStr-317x0:SdErrT31730">
<description></description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1092,7 +1092,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31731:AH">
<description>Turbine T-31730 break circuit temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1101,7 +1101,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31731:AHH">
<description>Turbine T-31730 break circuit temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1110,7 +1110,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31730:ALL">
<description>Turbine T-31730 inlet pressure too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1119,7 +1119,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31731:ALL">
<description>Turbine T-31730 low speed trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1128,7 +1128,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31755:AH">
<description>Turbine T-31730 outlet pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1137,7 +1137,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31755:AL">
<description>Turbine T-31730 outlet pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1146,7 +1146,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31755:ALL">
<description>Turbine T-31730 outlet pressure too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1155,7 +1155,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31731:AHH">
<description>Turbine T-31730 overspeed trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1164,7 +1164,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-AS-31731:Aval">
<description>Turbine T-31730 overspeed trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1173,7 +1173,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31730:AL">
<description>Warning: turbine T-31730 inlet temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1182,7 +1182,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31731:AL">
<description>Warning: turbine T-31730 low speed</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1191,7 +1191,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-31731:AH">
<description>Warning: turbine T-31730 overspeed</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1200,7 +1200,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-T-31730:SdPrsRatio">
<description>T-31730 pressure ratio high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1209,7 +1209,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TStr-317x0:SdHWS">
<description>T-31730 pressure ratio too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1218,7 +1218,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TStr:CondT31730">
<description>Condensation alarm JT Turbine (if PI-31602 &lt; 3.0 bar)</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1231,7 +1231,7 @@
<component name="ACCP Cold Compressor 3">
<pv name="CrS-ACCP:CRYO-FT-38821:AL">
<description>C-34700 cooling water flow low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1240,7 +1240,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-CC-34700:SdHWS">
<description>C-34700 Hard wired safety activated</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1249,7 +1249,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-CC-34700:SdTmpMtrHi">
<description>C-34700 high drive temperature trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1258,7 +1258,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-AS-347014:Aval">
<description>C-34700 high speed hardwired shutdown</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1267,7 +1267,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-347011:AH">
<description>C-34700 lower bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1276,7 +1276,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-347011:AHH">
<description>C-34700 lower bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1285,7 +1285,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-CC-34700:SdHard">
<description>C-34700 Shutdown hard</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1294,7 +1294,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-CC-34700:SdSoft">
<description>C-34700 Shutdown soft</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1303,7 +1303,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-34701:AHH">
<description>C-34700 speed too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1312,7 +1312,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-347012:AH">
<description>C-34700 upper bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1321,7 +1321,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-347012:AHH">
<description>C-34700 upper bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1332,7 +1332,7 @@
<component name="ACCP Cold Compressor 2">
<pv name="CrS-ACCP:CRYO-FT-38822:AL">
<description>C-34800 cooling water flow low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1341,7 +1341,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-CC-34800:SdHWS">
<description>C-34800 Hard wired safety activated</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1350,7 +1350,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-CC-34800:SdTmpMtrHi">
<description>C-34800 high drive temperature trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1359,7 +1359,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-AS-348014:Aval">
<description>C-34800 high speed hardwired shutdown</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1368,7 +1368,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-348011:AH">
<description>C-34800 lower bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1377,7 +1377,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-348011:AHH">
<description>C-34800 lower bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1386,7 +1386,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-CC-34800:SdHard">
<description>C-34800 Shutdown hard</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1395,7 +1395,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-CC-34800:SdSoft">
<description>C-34800 Shutdown soft</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1404,7 +1404,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-34801:AHH">
<description>C-34800 speed too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1413,7 +1413,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-348012:AH">
<description>C-34800 upper bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1422,7 +1422,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-348012:AHH">
<description>C-34800 upper bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1433,7 +1433,7 @@
<component name="ACCP Cold Compressor 1">
<pv name="CrS-ACCP:CRYO-FT-38823:AL">
<description>C-34900 cooling water flow low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1442,7 +1442,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-CC-34900:SdHWS">
<description>C-34900 Hard wired safety activated</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1451,7 +1451,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-CC-34900:SdTmpMtrHi">
<description>C-34900 high drive temperature trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1460,7 +1460,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-AS-349014:Aval">
<description>C-34900 high speed hardwired shutdown</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1469,7 +1469,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-349011:AH">
<description>C-34900 lower bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1478,7 +1478,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-349011:AHH">
<description>C-34900 lower bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1487,7 +1487,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-CC-34900:SdHard">
<description>C-34900 Shutdown hard</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1496,7 +1496,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-CC-34900:SdSoft">
<description>C-34900 Shutdown soft</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1505,7 +1505,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-ST-34901:AHH">
<description>C-34900 speed too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1514,7 +1514,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-349012:AH">
<description>C-34900 upper bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1523,7 +1523,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-349012:AHH">
<description>C-34900 upper bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1534,7 +1534,7 @@
<component name="ACCP Cold Compressor General">
<pv name="CrS-ACCP:CRYO-PDT-34905:AL">
<description>CC outlet flow too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1543,7 +1543,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-CC-34x00:SdGenHard">
<description>CC Hard shutdown</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1557,7 +1557,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-CC-34x00:SdGen">
<description>CC General shutdown</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1571,7 +1571,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-CC-34x00:SdSurge">
<description>CC Max surge oversteps reached.</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1585,7 +1585,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-34650:AH">
<description>CC string inlet pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1594,7 +1594,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-34650:AHH">
<description>CC string inlet pressure too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1603,7 +1603,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-34650:AH">
<description>CC string inlet temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1612,7 +1612,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-34650:AHH">
<description>CC string inlet temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1621,7 +1621,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-34950:AL">
<description>CC string outlet pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1630,7 +1630,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-34950:AHH">
<description>CC string outlet pressure too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1639,7 +1639,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-34891:AL">
<description>Possible 2-phase flow to CCs (if PI-34610 &lt; 2.3 bar)</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1648,7 +1648,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-34892:AL">
<description>Possible 2-phase flow to CCs (if PI-34652 &lt; 2.3 bar)</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1661,16 +1661,25 @@
<component name="ACCP Coldbox Vacuum">
<pv name="CrS-ACCP:CRYO-PT-39001:AL">
<description>Coldbox insulation vacuum below meas. range of sensor</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
<details>Check vacuum sensor</details>
</guidance>
</pv>
<pv name="CrS-ACCP:CRYO-LT-63000:AL">
<description>Dewar Alarm Level Low</description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
<details>Check dewar level</details>
</guidance>
</pv>
<pv name="CrS-ACCP:CRYO-PT-39001:AH">
<description>Coldbox insulation vacuum high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1679,7 +1688,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-39001:AHH">
<description>Coldbox insulation vacuum too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1693,7 +1702,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-M-39001:Sta">
<description>No signal from insulation vacuum pump P-39001</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1704,7 +1713,7 @@
<component name="ACCPColdbox General">
<pv name="CrS-ACCP:CRYO-PDT-31003:AH">
<description>Coldbox Warm End HP line pressure drop across filter high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1713,7 +1722,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31000:AH">
<description>Coldbox Warm End HP line temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1722,7 +1731,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31101:AH">
<description>Coldbox Warm End HP line temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1731,7 +1740,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-33101:AL">
<description>Coldbox Warm End LP line temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1740,7 +1749,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-32101:AL">
<description>Coldbox Warm End MP line temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1749,7 +1758,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-32101:ALL">
<description>Coldbox Warm End MP line temperature too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1758,7 +1767,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-34101:AL">
<description>Coldbox Warm End SP line temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1767,7 +1776,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-34101:ALL">
<description>Coldbox Warm End SP line temperature too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1776,7 +1785,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-32103:AL">
<description>MP inlet temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1785,7 +1794,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-Cbox:SdEMSTP">
<description>Sd cb - emergency stop</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1794,7 +1803,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-Cbox:SdOpenFuseCb">
<description>Sd cb - fuses fallen off stop (Check coldbox cabinet)</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1803,7 +1812,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-Cbox:SdOpenFuse">
<description>Sd cb - fuses fallen off stop (Check main cabinet)</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1812,7 +1821,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-31702:AH">
<description>HX-31700 outlet flow high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1821,7 +1830,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-33009:AL">
<description>HX-33010 outlet temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1830,7 +1839,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-33009:ALL">
<description>HX-33010 outlet temperature too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1839,7 +1848,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-38000:AL">
<description>Cooling water temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1848,7 +1857,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-38000:ALL">
<description>Cooling water temperature too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1857,7 +1866,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31801:AH">
<description>ScH supply coldbox outlet pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1866,7 +1875,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31801:AHH">
<description>ScH supply coldbox outlet pressure too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1875,7 +1884,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31801:AL">
<description>ScH supply pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1884,7 +1893,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31921:AH">
<description>Pressure in pure helium supply header high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1893,7 +1902,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-31702:AL">
<description>4.5K supply temperature too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1902,7 +1911,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-31641:AH">
<description>TS supply pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1916,7 +1925,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-32890:AH">
<description>Level in S-32890 high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1925,7 +1934,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-32890:AL">
<description>Level in S-32890 low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1934,7 +1943,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-32890:AHH">
<description>Level in S-32890 too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1943,7 +1952,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-32890:ALL">
<description>Level in S-32890 too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1952,7 +1961,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-LT-33711:AH">
<description>Level in S-33710 high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1961,7 +1970,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-33710:AH">
<description>Level in S-33710 high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1970,7 +1979,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-33710:AL">
<description>Level in S-33710 low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1979,7 +1988,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-LT-33711:AHH">
<description>Level in S-33710 too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1988,7 +1997,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-33710:AHH">
<description>Level in S-33710 too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -1997,7 +2006,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-33710:ALL">
<description>Level in S-33710 too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2006,7 +2015,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-33710:AH">
<description>S-33710 pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2015,7 +2024,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-32890:AH">
<description>Pressure in S-32890 too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2026,7 +2035,7 @@
<component name="ACCP Coldbox Helium Guard">
<pv name="CrS-ACCP:CRYO-PT-30500:AL">
<description>Inlet Safety Valve Header Subatmospheric pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2035,7 +2044,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-30500:AHH">
<description>Inlet Safety Valve Header Subatmospheric pressure too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2044,7 +2053,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-30100:AL">
<description>Helium Guard Header pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2053,7 +2062,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-30100:AHH">
<description>Helium Guard Header pressure too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2062,7 +2071,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-30100:ALL">
<description>Helium Guard Header pressure too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2073,7 +2082,7 @@
<component name="ACCP Coldbox Heaters">
<pv name="CrS-ACCP:CRYO-TS-328901:Aval">
<description>EH-32890-A temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2082,7 +2091,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TS-328903:Aval">
<description>EH-32890-B temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2091,7 +2100,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TS-337101:Aval">
<description>Heater EH-33710-A temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2100,7 +2109,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TS-337103:Aval">
<description>Heater EH-33710-B temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2109,7 +2118,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TS-318901:Aval">
<description>Heater R-31890-A temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2118,7 +2127,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TS-318903:Aval">
<description>Heater R-31890-B temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2127,7 +2136,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TS-316991:Aval">
<description>R-31699-A heater temperature</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2136,7 +2145,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TS-316993:Aval">
<description>R-31699-B heater temperature</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2145,7 +2154,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TS-316995:Aval">
<description>R-31699-C heater temperature</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2154,7 +2163,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TS-316997:Aval">
<description>R-31699-D heater temperature</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2163,7 +2172,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TS-328911:Aval">
<description>R-32891-A temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2172,7 +2181,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TS-328913:Aval">
<description>R-32891-B temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2183,7 +2192,7 @@
<component name="ACCP Dewar">
<pv name="CrS-ACCP:CRYO-LT-63001:AH">
<description>Dewar level high (D-63000)</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2192,7 +2201,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-LT-63001:AHH">
<description>Dewar level too high (D-63000)</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2205,7 +2214,7 @@
<component name="ACCP WCS Helium Guard">
<pv name="CrS-ACCP:CRYO-PT-20100:AL">
<description>Panel GMP Guard system header pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2214,7 +2223,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-20500:AL">
<description>Safety Valve Header Subatmospheric pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2225,7 +2234,7 @@
<component name="ACCP WCS ORS and GMP">
<pv name="CrS-ACCP:CRYO-PT-22601:AH">
<description>Buffer tank (aux) pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2234,7 +2243,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-22601:AL">
<description>Buffer tank (aux) pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2248,7 +2257,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-22600:AH">
<description>Buffer tank (main) pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2257,7 +2266,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-22600:AL">
<description>Buffer tank (main) pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2271,7 +2280,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-21632:AH">
<description>GMP HP line pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2280,7 +2289,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-21632:AL">
<description>GMP HP line pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2289,7 +2298,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-21632:AHH">
<description>GMP HP line pressure too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2298,7 +2307,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-22631:AH">
<description>GMP MP line pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2307,7 +2316,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-22631:AL">
<description>GMP MP line pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2316,7 +2325,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-LS-27430:Aval">
<description>S-21430 coalescer level high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2325,7 +2334,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21404:AH">
<description>Coalescer outlet temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2334,7 +2343,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21404:AHH">
<description>Coalescer outlet temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2343,7 +2352,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-S-21410:EvacLong">
<description>Trp - Coalescer 1 (S21410) Evacuation time too long</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2352,7 +2361,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-S-21410:EvacShort">
<description>Trp - Coalescer 1 (S21410) Evacuation time too short</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2361,7 +2370,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-S-21420:EvacLong">
<description>Trp - Coalescer 2 (S21420) Evacuation time too long</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2370,7 +2379,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-S-21420:EvacShort">
<description>Trp - Coalescer 2 (S21420) Evacuation time too short</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2383,7 +2392,7 @@
<component name="ACCP WCS HP Compressor">
<pv name="CrS-ACCP:CRYO-C-21000:EmStopHPActv">
<description>C21000 emergency stop HP active</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2397,7 +2406,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-C-21000:GroupTrp">
<description>C21000 Compressor trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2411,7 +2420,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-21004:AH">
<description>HP compressor discharge pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2420,7 +2429,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-21004:AL">
<description>HP compressor discharge pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2429,7 +2438,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-21004:AHH">
<description>HP compressor discharge pressure too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2438,7 +2447,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21202:AH">
<description>HP discharge temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2447,7 +2456,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21202:AHH">
<description>HP discharge temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2456,7 +2465,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-27030:AH">
<description>HP forward oil temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2465,7 +2474,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-27030:AHH">
<description>HP forward oil temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2474,7 +2483,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-VMT-21200:AH">
<description>HP FR / DS / 45° housing vibration high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2483,7 +2492,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-VMT-21200:AHH">
<description>HP FR / DS / 45° housing vibration too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2492,7 +2501,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-VMT-21201:AH">
<description>HP FR / SS / 45° housing vibration high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2501,7 +2510,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-VMT-21201:AHH">
<description>HP FR / SS / 45° housing vibration too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2510,7 +2519,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21210:AH">
<description>HP FR/DS bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2519,7 +2528,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21210:AHH">
<description>HP FR/DS bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2528,7 +2537,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21208:AH">
<description>HP FR/SS bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2537,7 +2546,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21208:AHH">
<description>HP FR/SS bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2546,7 +2555,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-FT-28011:AL">
<description>HP gas cooler cooling water volume flow low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2555,7 +2564,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-29005:AL">
<description>HP instrument air pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2564,7 +2573,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-FT-28003:AL">
<description>HP main motor cooling water volume flow low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2573,7 +2582,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21228:AH">
<description>HP main motor drive end side bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2582,7 +2591,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21228:AHH">
<description>HP main motor drive end side bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2591,7 +2600,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21226:AH">
<description>HP main motor non driven end bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2600,7 +2609,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21226:AHH">
<description>HP main motor non driven end bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2609,7 +2618,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21220:AH">
<description>HP main motor winding temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2618,7 +2627,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21222:AH">
<description>HP main motor winding temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2627,7 +2636,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21224:AH">
<description>HP main motor winding temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2636,7 +2645,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21220:AHH">
<description>HP main motor winding temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2645,7 +2654,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21222:AHH">
<description>HP main motor winding temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2654,7 +2663,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21224:AHH">
<description>HP main motor winding temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2663,7 +2672,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21206:AH">
<description>HP MR/DS bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2672,7 +2681,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21206:AHH">
<description>HP MR/DS bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2681,7 +2690,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21204:AH">
<description>HP MR/SS bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2690,7 +2699,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21204:AHH">
<description>HP MR/SS bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2699,7 +2708,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-29008:AL">
<description>HP oil and gas instrument air Unit pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2708,7 +2717,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21000:AH">
<description>HP oil and gas skid after gas cooler temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2717,7 +2726,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-21012:AH">
<description>HP oil and gas skid oil separator differential pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2726,7 +2735,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-FT-28010:AL">
<description>HP oil cooler cooling water volume flow low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2735,7 +2744,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-27040:AH">
<description>HP oil filter differential pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2744,7 +2753,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-LT-27012:AH">
<description>HP oil separator level high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2753,7 +2762,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-LT-27012:AL">
<description>HP oil separator level low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2762,7 +2771,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-LT-27010:AH">
<description>HP oil vessel level high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2771,7 +2780,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-LT-27010:AL">
<description>HP oil vessel level low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2780,7 +2789,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-27040:AL">
<description>HP oil vessel oil temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2789,7 +2798,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-21200:AH">
<description>HP suction pressure high </description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2798,7 +2807,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-21200:AL">
<description>HP suction pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2807,7 +2816,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-21200:ALL">
<description>HP suction pressure too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2816,7 +2825,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-27023A:AH">
<description>HP suction strainer pump A differential pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2825,7 +2834,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-27023B:AH">
<description>HP suction strainer pump B differential pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2834,7 +2843,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21200:AH">
<description>HP suction temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2843,7 +2852,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-21200:AL">
<description>HP suction temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2852,7 +2861,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-27030:AL">
<description>HP VMY oil pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2861,27 +2870,18 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-27030:ALL">
<description>HP VMY oil pressure too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
<details>1. Clean / replace the oil filter according chapter 7.3.12 (page 103). 2. Inform customer service. 3. Reduce oil injection rate. 4. Replace oil pressure regulating valve.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:CRYO-C-21000:ComFail">
<description>Trip - Communication fail</description>
<latching>true</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
<details>Depend on root cause.&#10;Contact Linde or Aerzen support</details>
</guidance>
</pv>
</component>
<component name="ACCP WCS LP Compressor">
<pv name="CrS-ACCP:CRYO-C-23000:GroupTrp">
<description>C23000 LP Compressor group trip</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2895,7 +2895,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-C-23000:OnFlt">
<description>C23000 starting time compressor too long / LP</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2904,7 +2904,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-23001:AH">
<description>LP compressor discharge pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2913,7 +2913,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-23001:AL">
<description>LP compressor discharge pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2922,7 +2922,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-23001:AHH">
<description>LP compressor discharge pressure too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2931,7 +2931,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23002:AH">
<description>LP discharge temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2940,7 +2940,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23002:AHH">
<description>LP discharge temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2949,7 +2949,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-VMT-23000:AH">
<description>LP FR / DS / 45° housing vibration high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2958,7 +2958,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-VMT-23000:AHH">
<description>LP FR / DS / 45° housing vibration high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2967,7 +2967,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-VMT-23001:AH">
<description>LP FR / SS / 45° housing vibration high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2976,7 +2976,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-VMT-23001:AHH">
<description>LP FR / SS / 45° housing vibration too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2985,7 +2985,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23010:AH">
<description>LP FR/DS bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -2994,7 +2994,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23010:AHH">
<description>LP FR/DS bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3003,7 +3003,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23008:AH">
<description>LP FR/SS bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3012,7 +3012,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23008:AHH">
<description>LP FR/SS bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3021,7 +3021,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-29003:AL">
<description>LP instrument air pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3030,7 +3030,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-FT-28002:AL">
<description>LP main motor cooling water volume flow low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3039,7 +3039,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-US-23028:AH">
<description>LP main motor drive end side bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3048,7 +3048,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23028:AHH">
<description>LP main motor drive end side bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3057,7 +3057,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23026:AH">
<description>LP main motor non driven end bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3066,7 +3066,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23026:AHH">
<description>LP main motor non driven end bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3075,7 +3075,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23020:AH">
<description>LP main motor winding temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3084,7 +3084,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23022:AH">
<description>LP main motor winding temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3093,7 +3093,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23024:AH">
<description>LP main motor winding temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3102,7 +3102,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23020:AHH">
<description>LP main motor winding temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3111,7 +3111,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23022:AHH">
<description>LP main motor winding temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3120,7 +3120,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23024:AHH">
<description>LP main motor winding temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3129,7 +3129,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23006:AH">
<description>LP MR/DS bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3138,7 +3138,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23006:AHH">
<description>LP MR/DS bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3147,7 +3147,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23004:AH">
<description>LP MR/SS bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3156,7 +3156,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23004:AHH">
<description>LP MR/SS bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3165,7 +3165,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-23000:AL">
<description>LP suction pressure after Suction strain pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3174,7 +3174,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-23000:AH">
<description>LP suction pressure after Suction strain pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3183,7 +3183,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-23000:ALL">
<description>LP suction pressure after Suction strain pressure too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3192,7 +3192,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23000:AH">
<description>LP suction temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3201,7 +3201,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-23000:AL">
<description>LP suction temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3210,7 +3210,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-27010:AL">
<description>LP VMY oil pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3219,7 +3219,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-27010:ALL">
<description>LP VMY oil pressure too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3228,7 +3228,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-23099:AH">
<description>LP WC Inlet pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3237,7 +3237,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-23099:AL">
<description>LP WC Inlet pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3246,16 +3246,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-US-27206:NotOpen">
<description>PV27206 oil injection valve not open / LP</description>
<latching>true</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
<details>Depend on root cause.&#10;Contact Linde or Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:CRYO-C-23000:ComFail">
<description>Trip - Communication fail</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3266,7 +3257,7 @@
<component name="ACCP WCS SP Compressor">
<pv name="CrS-ACCP:CRYO-C-24000:GroupTrp">
<description>C24000 Compressor group trip SP</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3280,7 +3271,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-C-24000:OnFlt">
<description>C24000 starting time compressor to long / SP</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3289,7 +3280,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-24000:AH">
<description>SP after Suction strain suction pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3298,7 +3289,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-24000:AL">
<description>SP after Suction strain suction pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3307,7 +3298,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-24000:ALL">
<description>SP after Suction strain suction pressure too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3316,7 +3307,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-24001:AH">
<description>SP compressor discharge pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3325,7 +3316,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-24001:AL">
<description>SP compressor discharge pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3334,7 +3325,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-24001:AHH">
<description>SP compressor discharge pressure too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3343,7 +3334,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24002:AH">
<description>SP discharge temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3352,7 +3343,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24002:AHH">
<description>SP discharge temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3361,7 +3352,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-VMT-24000:AH">
<description>SP FR / DS / 45° compressor housing vibration high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3370,7 +3361,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-VMT-24000:AHH">
<description>SP FR / DS / 45° compressor housing vibration too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3379,7 +3370,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-VMT-24001:AH">
<description>SP FR / SS / 45° compressor housing vibration high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3388,7 +3379,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-VMT-24001:AHH">
<description>SP FR / SS / 45° compressor housing vibration too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3397,7 +3388,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24010:AH">
<description>SP FR/DS compressor bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3406,7 +3397,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24010:AHH">
<description>SP FR/DS compressor bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3415,7 +3406,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24008:AH">
<description>SP FR/SS compressor bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3424,7 +3415,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24008:AHH">
<description>SP FR/SS compressor bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3433,7 +3424,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-29001:AL">
<description>SP instrument air pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3442,7 +3433,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-FT-28012:AL">
<description>SP main motor cooling water volume flow low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3451,7 +3442,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24028:AH">
<description>SP main motor drive end side bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3460,7 +3451,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24028:AHH">
<description>SP main motor drive end side bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3469,7 +3460,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24026:AH">
<description>SP main motor non driven end bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3478,7 +3469,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24026:AHH">
<description>SP main motor non driven end bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3487,7 +3478,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24020:AH">
<description>SP main motor winding temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3496,7 +3487,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24022:AH">
<description>SP main motor winding temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3505,7 +3496,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24024:AH">
<description>SP main motor winding temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3514,7 +3505,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24020:AHH">
<description>SP main motor winding temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3523,7 +3514,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24022:AHH">
<description>SP main motor winding temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3532,7 +3523,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24024:AHH">
<description>SP main motor winding temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3541,7 +3532,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24006:AH">
<description>SP MR/DS compressor bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3550,7 +3541,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24006:AHH">
<description>SP MR/DS compressor bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3559,7 +3550,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24004:AH">
<description>SP MR/SS compressor bearing temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3568,7 +3559,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24004:AHH">
<description>SP MR/SS compressor bearing temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3577,7 +3568,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-FT-27000:AL">
<description>SP oil forward mechanical seal volume flow low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3586,7 +3577,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-FT-27000:ALL">
<description>SP oil forward mechanical seal volume flow too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3595,7 +3586,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-27020:AH">
<description>SP return mechanical seal oil temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3604,7 +3595,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-27020:AHH">
<description>SP return mechanical seal oil temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3613,7 +3604,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24000:AH">
<description>SP suction temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3622,7 +3613,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-24000:AL">
<description>SP suction temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3631,7 +3622,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-27000:AL">
<description>SP VMY oil pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3640,7 +3631,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-27000:ALL">
<description>SP VMY oil pressure too low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3649,7 +3640,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-24099:AH">
<description>SP WC Inlet pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3658,7 +3649,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-24099:AL">
<description>SP WC Inlet pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3667,7 +3658,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-US-27106:NotOpen">
<description>PV27106 oil injection valve not open / SP</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3676,16 +3667,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-M-24000:Flt">
<description>M24000 main motor fault / SP</description>
<latching>true</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
<details>Depend on root cause.&#10;Contact Linde or Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:CRYO-C-24000:ComFail">
<description>Trip - Communication fail</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3696,7 +3678,7 @@
<component name="ACCP WCS LP+SP General">
<pv name="CrS-ACCP:CRYO-C-24000:EmStopActv">
<description>Emergency Stop active SP+LP</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3710,7 +3692,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-27003:AH">
<description>SP and LP forward oil temperature high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3719,7 +3701,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-27003:AHH">
<description>SP and LP forward oil temperature too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3728,7 +3710,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-FT-28001:AL">
<description>SP and LP gas cooler cooling water volume flow low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3737,7 +3719,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-29006:AL">
<description>SP and LP oil and gas instrument air Unit pressure low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3746,7 +3728,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-22012:AH">
<description>SP and LP oil and gas skid oil separator differential pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3755,7 +3737,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-22200:AH">
<description>SP and LP oil and gas skid temperature after gas cooler high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3764,7 +3746,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-22200:AHH">
<description>SP and LP oil and gas skid temperature after gas cooler too high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3773,7 +3755,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-FT-28000:AL">
<description>SP and LP oil cooler cooling water volume flow low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3782,7 +3764,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PDT-27020:AH">
<description>SP and LP oil filter differential pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3791,7 +3773,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-LT-27002:AH">
<description>SP and LP oil separator level high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3800,7 +3782,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-LT-27002:AL">
<description>SP and LP oil separator level low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3809,7 +3791,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-LT-27000:AH">
<description>SP and LP oil vessel level high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3818,7 +3800,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-LT-27000:AL">
<description>SP and LP oil vessel level low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3827,7 +3809,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-TT-27014:AL">
<description>SP and LP oil vessel oil temperature low</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3836,7 +3818,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-27021A:AH">
<description>SP and LP suction strainer pump A differential pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3845,7 +3827,7 @@
</pv>
<pv name="CrS-ACCP:CRYO-PT-27021B:AH">
<description>SP and LP suction strainer pump B differential pressure high</description>
<latching>true</latching>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Operator Action]</title>
......@@ -3853,5 +3835,1309 @@
</guidance>
</pv>
</component>
<component name="ACCP WCS BCP Compressor">
<pv name="CrS-ACCP:Cryo-C-91000:GroupTrp">
<description> ACCP - C24000 Compressor group trip BCP</description>
<latching>false</latching>
<annunciating>true</annunciating>
<delay>4</delay>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Call Cryo on-call +46 46 888 31 66 Tell them that ACCP BCP Compressor have tripped</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-C-91000:PowerRailF">
<description> G901 Power-Rail fault</description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-C-91000:PhaseSeqF">
<description> K11 Phase sequence fault</description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-C-91000:OpticalLinkModF">
<description> K461 optical link modul fault </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-C-91000:CommunicationTrip">
<description> Communication with ACCP fault</description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-C-91000:StopTimeToLong">
<description> Comprerssor Stopping Time to long</description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-C-91000:ExternalRelease">
<description> Compressor external release signal from ACCP Fault</description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-C-91000:AllDrivesnotAuto">
<description> Compressor NOT all drives in Auto </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\n</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-C-91000:StartTimeToLong">
<description> Compressor Start Time to long</description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-C-91000:ControlVolFault">
<description> Control voltage A DC 24 V fault </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-C-91000:ControlVolFault_1">
<description> Control voltage B DC 24 V fault </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-C-91000:EmerStop">
<description> Emergency stop control cabinet active</description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check Painel Emergency Stop push button</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-CV-97020:Discrepancycontrol">
<description> CV 97020 capacity valve: Discrepancy control - feedback fault </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-CV-91000:PositionFault">
<description> CV-91000 position fault bypass control valve </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-CV-98010:PositionFault">
<description> CV-98010 position fault cooling water control valve motor </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-CV-98011:PositionFault">
<description> CV-98011 position fault cooling water control valve oil cooler </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-CV-98012:PositionFault">
<description> CV-98012 position fault cooling water control valve gas cooler </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-EH-91000:Discrepancycontrol">
<description> EH-91000 Standstill heating main drive: Discrepancy control - feedback fault </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-EH-91000:MotorprotectionSw">
<description> EH-91000 Standstill heating main drive: Motor protection switch </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-EH-97201:Discrepancycontrol">
<description> EH-97201 oil heater: Discrepancy control - feedback faul </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-EH-97201:MotorprotectionSw">
<description> EH-97201 oil heater: Motor protection switch </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-FT-97000:LO">
<description> FT-97000 volume flow oil forward mechanical seal: Limit L </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-FT-97000:LOLO">
<description> FT-97000 volume flow oil forward mechanical seal: Limit LL </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-FT-97000:Qbad">
<description> FT-97000 volume flow oil forward mechanical seal: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-FT-98003:LO">
<description> FT-98003 volume flow cooling water motor: Limit L </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-FT-98003:Qbad">
<description> FT-98003 volume flow cooling water motor: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-FT-98010:LO">
<description> FT-98010 volume flow cooling water oil cooler: Limit L </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-FT-98010:Qbad">
<description> FT-98010 volume flow cooling water oil cooler: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-FT-98011:LO">
<description> FT-98011 volume flow cooling water gas cooler: Limit L </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-FT-98011:Qbad">
<description> FT-98011 volume flow cooling water gas cooler: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-GT-91200:PositionFault">
<description> GT-91200 slide valve position: Position fault </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-CV-91000:Sta">
<description> GT-91204 position transmitter bypass control valve: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-CV-97020:PositionFault">
<description> GT-91208 position transmitter slide valve speed control valve: Position fault </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-CV-97020:Sta">
<description> GT-91208 position transmitter slide valve speed control valve: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TV-97014:PositionFault">
<description> GT-97009 position transmitter oil temperature control valve: Position fault </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TV-97014:Sta">
<description> GT-97009 position transmitter oil temperature control valve: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-CV-98012:Sta">
<description> GT-98012 position transmitter cooling water control valve gas cooler: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-CV-98010:Sta">
<description> GT-98014 position transmitter cooling water control valve motor: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-CV-98011:Sta">
<description> GT-98015 position transmitter cooling water control valve oil cooler: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-C-91000:LS91220_LeakCoolWa">
<description> LS-91220 leakage cooling-water main drive </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-LT-97010:HI">
<description> LT-97010 level oil vessel: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-LT-97010:LO">
<description> LT-97010 level oil vessel: Limit L </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-LT-97010:Qbad">
<description> LT-97010 level oil vessel: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-LT-97012:HI">
<description> LT-97012 level oil separator: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-LT-97012:LO">
<description> LT-97012 level oil separator: Limit L </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-LT-97012:Qbad">
<description> LT-97012 level oil separator: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-M-91000:Discrepancycontrol">
<description> M-91000 main drive: Discrepancy control - feedback fault </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-M-91000:MotorprotectionSw">
<description> M-91000 main drive: Motor protection switch </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-SC-97012A:Discrepancycontrol">
<description> M-97012A oil pump A: Discrepancy control - feedback fault </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-SC-97012A:MotorprotectionSw">
<description> M-97012A oil pump A: Motor protection switch </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-SC-97012B:Discrepancycontrol">
<description> M-97012B oil pump B: Discrepancy control - feedback fault </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-SC-97012B:MotorprotectionSw">
<description> M-97012B oil pump B: Motor protection switch </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PDT-91005:HI">
<description> PDT-91005 differential pressure suction side block valve and suction strainer: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PDT-91005:Qbad">
<description> PDT-91005 differential pressure suction side block valve and suction strainer: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PDT-91006:HI">
<description> PDT-91006 025 bar differential pressure compressor: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PDT-91006:HIHI">
<description> PDT-91006 025 bar differential pressure compressor: Limit HH </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PDT-91006:LO">
<description> PDT-91006 025 bar differential pressure compressor: Limit L </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PDT-91006:Qbad">
<description> PDT-91006 025 bar differential pressure compressor: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PDT-91012:HI">
<description> PDT-91012 differential pressure oil separator: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PDT-91012:Qbad">
<description> PDT-91012 differential pressure oil separator: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PDT-97030:LO">
<description> PDT-97030 oil pressure VMY: Limit L </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>1. Clean / replace the oil filter according chapter 7.3.12 (page 103). 2. Inform customer service. 3. Reduce oil injection rate. 4. Replace oil pressure regulating valve.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PDT-97030:LOLO">
<description> PDT-97030 oil pressure VMY: Limit LL </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>1. Clean / replace the oil filter according chapter 7.3.12 (page 103). 2. Inform customer service. 3. Reduce oil injection rate. 4. Replace oil pressure regulating valve.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PDT-97030:Qbad">
<description> PDT-97030 oil pressure VMY: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>1. Clean / replace the oil filter according chapter 7.3.12 (page 103). 2. Inform customer service. 3. Reduce oil injection rate. 4. Replace oil pressure regulating valve.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PDT-97040:HI">
<description> PDT-97040 differential pressure oil filter: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nManually switch to the clean oil filter (double oil filter system) at compressor skid.\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PDT-97040:Qbad">
<description> PDT-97040 differential pressure oil filter: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PT-90000:HI">
<description> PT-90000 guard system pressure: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PT-90000:LO">
<description> PT-90000 guard system pressure: Limit L </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PT-90000:Qbad">
<description> PT-90000 guard system pressure: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PT-91000:HI">
<description> PT-91000 suction pressure after suction strainer: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>1. Generate even supply pressure. 2. Position the capacity slide valve correctly.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PT-91000:LO">
<description> PT-91000 suction pressure after suction strainer: Limit L </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>1. Generate even supply pressure. 2. Position the capacity slide valve correctly.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PT-91000:LOLO">
<description> PT-91000 suction pressure after suction strainer: Limit LL </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>1. Generate even supply pressure. 2. Position the capacity slide valve correctly.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PT-91000:Qbad">
<description> PT-91000 suction pressure after suction strainer: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>1. Generate even supply pressure. 2. Position the capacity slide valve correctly.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PT-91003:Qbad">
<description> PT-91003 suction pressure: Limit QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>1. Generate even supply pressure. 2. Position the capacity slide valve correctly.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PT-91004:HI">
<description> PT-91004 discharge pressure compressor: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data.\nCheck the position of the output control gate; correct if necessary.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PT-91004:HIHI">
<description> PT-91004 discharge pressure compressor: Limit HH </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data.\nCheck the position of the output control gate; correct if necessary.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PT-91004:Qbad">
<description> PT-91004 discharge pressure compressor: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data.\nCheck the position of the output control gate; correct if necessary.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PT-91010:Qbad">
<description> PT-91010 discharge pressure after gas cooler: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PT-98005:LO">
<description> PT-99005 Pressure instrument air: Limit L </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>1. Check operating data.2. Contact Instrument air supply.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PT-98005:Qbad">
<description> PT-99005 Pressure instrument air: Limit QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PV-91000:Discrepancycontrol">
<description> PV-91000 suction side valve: Discrepancy control - feedback fault </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PV-91000:ValveFault">
<description> PV-91000 suction side valve: Fault </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PV-97406:Discrepancycontrol">
<description> PV-97406 Oil injection valve: Discrepancy control - feedback fault </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PV-97406:ValveFault">
<description> PV-97406 Oil injection valve: Fault </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PV-97415:Discrepancycontrol">
<description> PV-97415 Oil pre-lubrication valve: Discrepancy control - feedback fault </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-PV-97415:ValveFault">
<description> PV-97415 Oil pre-lubrication valve: Fault </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91000:HI">
<description> TI-91000 temperature after gas cooler: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91000:HIHI">
<description> TI-91000 temperature after gas cooler: Limit HH </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91000:Qbad">
<description> TI-91000 temperature after gas cooler: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91200:HI">
<description> TI-91200 suction temperature: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Ensure that the intake temperature is correct. Inform supervisor immediately.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91200:LO">
<description> TI-91200 suction temperature: Limit L </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Ensure that the intake temperature is correct. Inform supervisor immediately.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91200:Qbad">
<description> TI-91200 suction temperature: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Ensure that the intake temperature is correct. Inform supervisor immediately.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91202:HI">
<description> TI-91202 discharge temperature: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check for correct pressure ration.\nCheck the oil injection volume; correct if necessary</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91202:HIHI">
<description> TI-91202 discharge temperature: Limit HH </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check for correct pressure ration.\nCheck the oil injection volume; correct if necessary</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91202:Qbad">
<description> TI-91202 discharge temperature: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check for correct pressure ration.\nCheck the oil injection volume; correct if necessary</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91204:HI">
<description> TI-91204 compressor bearing temperature MRSS: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check for correct pressure ration.\nCheck the oil injection volume; correct if necessary</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91204:HIHI">
<description> TI-91204 compressor bearing temperature MRSS: Limit HH </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check for correct pressure ration.\nCheck the oil injection volume; correct if necessary</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91204:Qbad">
<description> TI-91204 compressor bearing temperature MRSS: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check for correct pressure ration.\nCheck the oil injection volume; correct if necessary</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91206:HI">
<description> TI-91206 compressor bearing temperature MRDS: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check for correct pressure ration.\nCheck the oil injection volume; correct if necessary</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91206:HIHI">
<description> TI-91206 compressor bearing temperature MRDS: Limit HH </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check for correct pressure ration.\nCheck the oil injection volume; correct if necessary</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91206:Qbad">
<description> TI-91206 compressor bearing temperature MRDS: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check for correct pressure ration.\nCheck the oil injection volume; correct if necessary</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91208:HI">
<description> TI-91208 compressor bearing temperature FRSS: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data.\Check the lube oil temperature and pressure; correct if necessary</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91208:HIHI">
<description> TI-91208 compressor bearing temperature FRSS: Limit HH </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data.\Check the lube oil temperature and pressure; correct if necessary</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91208:Qbad">
<description> TI-91208 compressor bearing temperature FRSS: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data.\Check the lube oil temperature and pressure; correct if necessary</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91210:HI">
<description> TI-91210 compressor bearing temperature FRDS: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data.\Check the lube oil temperature and pressure; correct if necessary</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91210:HIHI">
<description> TI-91210 compressor bearing temperature FRDS: Limit HH </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data.\Check the lube oil temperature and pressure; correct if necessary</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91210:Qbad">
<description> TI-91210 compressor bearing temperature FRDS: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data.\Check the lube oil temperature and pressure; correct if necessary</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91220:HI">
<description> TI-91220 winding temperature U: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91220:HIHI">
<description> TI-91220 winding temperature U: Limit HH </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91220:Qbad">
<description> TI-91220 winding temperature U: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91222:HI">
<description> TI-91222 winding temperature V: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91222:HIHI">
<description> TI-91222 winding temperature V: Limit HH </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91222:Qbad">
<description> TI-91222 winding temperature V: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91224:HI">
<description> TI-91224 winding temperature W: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91224:HIHI">
<description> TI-91224 winding temperature W: Limit HH </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91224:Qbad">
<description> TI-91224 winding temperature W: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91226:HI">
<description> TI-91226 bearing temperature non driven end motor: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91226:HIHI">
<description> TI-91226 bearing temperature non driven end motor: Limit HH </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91226:Qbad">
<description> TI-91226 bearing temperature non driven end motor: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91228:HI">
<description> TI-91228 bearing temperature driven end motor: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91228:HIHI">
<description> TI-91228 bearing temperature driven end motor: Limit HH </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-91228:Qbad">
<description> TI-91228 bearing temperature driven end motor: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-97020:HIHI">
<description> TI-97020 oil temperature return mechanical seal: Limit HH </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-97020:LO">
<description> TI-97020 oil temperature return mechanical seal: Limit L </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-97020:Qbad">
<description> TI-97020 oil temperature return mechanical seal: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-97030:HI">
<description> TI-97030 oil temperature oil supply: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-97030:HIHI">
<description> TI-97030 oil temperature oil supply: Limit HH </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-97030:Qbad">
<description> TI-97030 oil temperature oil supply: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-97036:Qbad">
<description> TI-97036 oil temperature outlet oil cooler: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-97040:LO">
<description> TI-97040 oil temperature oil vessel: Limit L </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>1. Check oil cooler output and adjust if necessary. 2. Replace oil pressure regulating valve.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-97040:Qbad">
<description> TI-97040 oil temperature oil vessel: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>1. Check oil cooler output and adjust if necessary. 2. Replace oil pressure regulating valve.</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-97044:Qbad">
<description> TI-97044 oil temperature downstream oil pump: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-98020:Qbad">
<description> TI-98020 cooling water temperature return gas cooler: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-98022:Qbad">
<description> TI-98022 cooling water temperature return oil cooler: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-TT-98045:Qbad">
<description> TI-98045 cooling water temperature return motor: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data..\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-VMT-91200:HI">
<description> VMI-91200 compressor housing vibration FR DS 45ー: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data.\nCheck the oil drainage; ensure unobstructed backflow.\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-VMT-91200:HIHI">
<description> VMI-91200 compressor housing vibration FR DS 45ー: Limit HH </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data.\nCheck the oil drainage; ensure unobstructed backflow.\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-VMT-91200:Qbad">
<description> VMI-91200 compressor housing vibration FR DS 45ー: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data.\nCheck the oil drainage; ensure unobstructed backflow.\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-VMT-91201:HI">
<description> VMI-91201 compressor housing vibration FR SS 45ー: Limit H </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data.\nCheck the oil drainage; ensure unobstructed backflow.\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-VMT-91201:HIHI">
<description> VMI-91201 compressor housing vibration FR SS 45ー: Limit HH </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data.\nCheck the oil drainage; ensure unobstructed backflow.\nContact Aerzen support</details>
</guidance>
</pv>
<pv name="CrS-ACCP:Cryo-VMT-91201:Qbad">
<description> VMI-91201 compressor housing vibration FR DS 45ー: QBAD </description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details>Check operating data.\nCheck the oil drainage; ensure unobstructed backflow.\nContact Aerzen support</details>
</guidance>
</pv>
</component>
</component>
<component name="PLC Communication">
<pv name="CrS-ACCP:SC-FSM-300:CommError">
<description>ACCP-1500 PLC failed to communicate with APPC-400 PLC</description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details> Check the Status of the ACCP-400 PLC in the G02 Coldbox Building CXB </details>
</guidance>
</pv>
<pv name="CrS-ACCP:CRYO-C-21000:ComFail">
<description>ACCP-400 PLC failed to communicate with HP-400 PLC or Compressor Trip</description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details> Check the Status of the HP PLC in the G04 Helium Compressor Building HCB. Contact Aerzen for support.
</details>
</guidance>
</pv>
<pv name="CrS-ACCP:CRYO-C-23000:ComFail">
<description>ACCP-400 PLC failed to communicate with LP-400 PLC or Compressor Trip</description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details> Check the Status of the L-400 PLC in the G04 Helium Compressor Building HCB. Contact Aerzen for support.
</details>
</guidance>
</pv>
<pv name="CrS-ACCP:CRYO-C-24000:ComFail">
<description>ACCP-400 PLC failed to communicate with SP-400 PLC or Compressor Trip</description>
<latching>false</latching>
<annunciating>true</annunciating>
<guidance>
<title>[Cryo Operator Action]</title>
<details> Check the Status of the SP-400 PLC in the G04 Helium Compressor Building HCB. Contact Aerzen for support.
</details>
</guidance>
</pv>
</component>
</config>
\ No newline at end of file
This diff is collapsed.
This diff is collapsed.
This diff is collapsed.
This diff is collapsed.
This diff is collapsed.
This diff is collapsed.
This diff is collapsed.
This diff is collapsed.
......@@ -1260,6 +1260,7 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<!--
<pv name="ConVen-H09:HVAC-Ahu-100:Fault">
<description>HVAC alarm ConVen-H09:HVAC-Ahu-100:Fault</description>
<latching>false</latching>
......@@ -1310,5 +1311,6 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
-->
</component>
</config>
This diff is collapsed.
......@@ -4,43 +4,13 @@
input xls file: lss3.xlsx-->
<config name="LSS">
<component name="General">
<pv name="Tgt-LSS1172::NWCabStdIO">
<description>LSS NW Cabinet Standard IO Error</description>
<pv name="Tgt-LSS1172::HardwareErrorNW">
<description>LSS NW Cabinet Hardware Problem</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::NWCabSafetyIO">
<description>LSS NW Cabinet Safety IO Error</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::NWCabDriveStd">
<description>LSS NW Cabinet Standard Drive Error</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::NWCabDriveSafety">
<description>LSS NW Cabinet Safety Drive Error</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::SECabStdIO">
<description>LSS NW Cabinet Standard IO Error</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::SECabSafetyIO">
<description>LSS NW Cabinet Safety IO Error</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::SECabDriveStd">
<description>LSS NW Cabinet Standard Drive Error</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::SECabDriveSafety">
<description>LSS NW Cabinet Safety Drive Error</description>
<pv name="Tgt-LSS1172::HardwareErrorSE">
<description>LSS SE Cabinet Hardware Problem</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
......@@ -51,12 +21,12 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W1-Disabled">
<pv name="Tgt-LSS1172::W1-DisabledShutterAlarm">
<description>Shutter disabled by operator.</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W1-OperatorRequired">
<pv name="Tgt-LSS1172::W1-OperatorRequiredAlarm">
<description>Operator input required.</description>
<latching>false</latching>
<annunciating>false</annunciating>
......@@ -123,12 +93,12 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W2-Disabled">
<pv name="Tgt-LSS1172::W2-DisabledShutterAlarm">
<description>Shutter disabled by operator.</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W2-OperatorRequired">
<pv name="Tgt-LSS1172::W2-OperatorRequiredAlarm">
<description>Operator input required.</description>
<latching>false</latching>
<annunciating>false</annunciating>
......@@ -195,12 +165,12 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W3-Disabled">
<pv name="Tgt-LSS1172::W3-DisabledShutterAlarm">
<description>Shutter disabled by operator.</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W3-OperatorRequired">
<pv name="Tgt-LSS1172::W3-OperatorRequiredAlarm">
<description>Operator input required.</description>
<latching>false</latching>
<annunciating>false</annunciating>
......@@ -267,12 +237,12 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W4-Disabled">
<pv name="Tgt-LSS1172::W4-DisabledShutterAlarm">
<description>Shutter disabled by operator.</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W4-OperatorRequired">
<pv name="Tgt-LSS1172::W4-OperatorRequiredAlarm">
<description>Operator input required.</description>
<latching>false</latching>
<annunciating>false</annunciating>
......@@ -339,12 +309,12 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W5-Disabled">
<pv name="Tgt-LSS1172::W5-DisabledShutterAlarm">
<description>Shutter disabled by operator.</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W5-OperatorRequired">
<pv name="Tgt-LSS1172::W5-OperatorRequiredAlarm">
<description>Operator input required.</description>
<latching>false</latching>
<annunciating>false</annunciating>
......@@ -411,12 +381,12 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W6-Disabled">
<pv name="Tgt-LSS1172::W6-DisabledShutterAlarm">
<description>Shutter disabled by operator.</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W6-OperatorRequired">
<pv name="Tgt-LSS1172::W6-OperatorRequiredAlarm">
<description>Operator input required.</description>
<latching>false</latching>
<annunciating>false</annunciating>
......@@ -483,12 +453,12 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W7-Disabled">
<pv name="Tgt-LSS1172::W7-DisabledShutterAlarm">
<description>Shutter disabled by operator.</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W7-OperatorRequired">
<pv name="Tgt-LSS1172::W7-OperatorRequiredAlarm">
<description>Operator input required.</description>
<latching>false</latching>
<annunciating>false</annunciating>
......@@ -555,12 +525,12 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W8-Disabled">
<pv name="Tgt-LSS1172::W8-DisabledShutterAlarm">
<description>Shutter disabled by operator.</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W8-OperatorRequired">
<pv name="Tgt-LSS1172::W8-OperatorRequiredAlarm">
<description>Operator input required.</description>
<latching>false</latching>
<annunciating>false</annunciating>
......@@ -627,12 +597,12 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W11-Disabled">
<pv name="Tgt-LSS1172::W11-DisabledShutterAlarm">
<description>Shutter disabled by operator.</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::W11-OperatorRequired">
<pv name="Tgt-LSS1172::W11-OperatorRequiredAlarm">
<description>Operator input required.</description>
<latching>false</latching>
<annunciating>false</annunciating>
......@@ -699,12 +669,12 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::N7-Disabled">
<pv name="Tgt-LSS1172::N7-DisabledShutterAlarm">
<description>Shutter disabled by operator.</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::N7-OperatorRequired">
<pv name="Tgt-LSS1172::N7-OperatorRequiredAlarm">
<description>Operator input required.</description>
<latching>false</latching>
<annunciating>false</annunciating>
......@@ -771,12 +741,12 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::N5-Disabled">
<pv name="Tgt-LSS1172::N5-DisabledShutterAlarm">
<description>Shutter disabled by operator.</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::N5-OperatorRequired">
<pv name="Tgt-LSS1172::N5-OperatorRequiredAlarm">
<description>Operator input required.</description>
<latching>false</latching>
<annunciating>false</annunciating>
......@@ -843,12 +813,12 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::S2-Disabled">
<pv name="Tgt-LSS1172::S2-DisabledShutterAlarm">
<description>Shutter disabled by operator.</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::S2-OperatorRequired">
<pv name="Tgt-LSS1172::S2-OperatorRequiredAlarm">
<description>Operator input required.</description>
<latching>false</latching>
<annunciating>false</annunciating>
......@@ -915,12 +885,12 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::S3-Disabled">
<pv name="Tgt-LSS1172::S3-DisabledShutterAlarm">
<description>Shutter disabled by operator.</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::S3-OperatorRequired">
<pv name="Tgt-LSS1172::S3-OperatorRequiredAlarm">
<description>Operator input required.</description>
<latching>false</latching>
<annunciating>false</annunciating>
......@@ -987,12 +957,12 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::E7-Disabled">
<pv name="Tgt-LSS1172::E7-DisabledShutterAlarm">
<description>Shutter disabled by operator.</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::E7-OperatorRequired">
<pv name="Tgt-LSS1172::E7-OperatorRequiredAlarm">
<description>Operator input required.</description>
<latching>false</latching>
<annunciating>false</annunciating>
......@@ -1059,12 +1029,12 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::E3-Disabled">
<pv name="Tgt-LSS1172::E3-DisabledShutterAlarm">
<description>Shutter disabled by operator.</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::E3-OperatorRequired">
<pv name="Tgt-LSS1172::E3-OperatorRequiredAlarm">
<description>Operator input required.</description>
<latching>false</latching>
<annunciating>false</annunciating>
......@@ -1131,12 +1101,12 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::E2-Disabled">
<pv name="Tgt-LSS1172::E2-DisabledShutterAlarm">
<description>Shutter disabled by operator.</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-LSS1172::E2-OperatorRequired">
<pv name="Tgt-LSS1172::E2-OperatorRequiredAlarm">
<description>Operator input required.</description>
<latching>false</latching>
<annunciating>false</annunciating>
......
This diff is collapsed.
This diff is collapsed.
This diff is collapsed.
This diff is collapsed.
......@@ -22,7 +22,6 @@
</pv>
<pv name="DTL-020:PBI-FC-001:WtrFlowOK">
<description>Water flow interlock for the DTL2 FC (disabled during DTL4 commissioning)</description>
<enabled>false</enabled>
<latching>true</latching>
<annunciating>true</annunciating>
<guidance>
......@@ -70,7 +69,6 @@
</pv>
<pv name="DTL-020:PBI-FC-001:BodyTempOK">
<description>Water temperature on the DTL2 FC (disabled during DTL4 commissioning)</description>
<enabled>false</enabled>
<latching>true</latching>
<annunciating>true</annunciating>
<guidance>
......@@ -107,7 +105,6 @@
</pv>
<pv name="DTL-020:PBI-FC-001:LimSwPressedCount">
<description>Motion timer for the DTL2 FC (disabled during DTL4 commissioning)</description>
<enabled>false</enabled>
<latching>true</latching>
<guidance>
<title>DTL2 FC probably stuck</title>
......@@ -116,7 +113,6 @@
</pv>
<pv name="DTL-040:PBI-FC-001:LimSwPressedCount">
<description>Motion timer for the DTL4 FC (disabled during DTL4 commissioning)</description>
<enabled>false</enabled>
<latching>true</latching>
<guidance>
<title>DTL4 FC probably stuck</title>
......@@ -163,7 +159,6 @@
</pv>
<pv name="DTL-020:PBI-FC-001:Voltage-R">
<description>Voltage readback for the DTL2 FC (disabled during DTL4 commissioning)</description>
<enabled>false</enabled>
<latching>true</latching>
<annunciating>true</annunciating>
<guidance>
......@@ -173,7 +168,6 @@
</pv>
<pv name="DTL-020:PBI-FC-001:HVCurrent-R">
<description>Current readback for the DTL2 FC (disabled during DTL4 commissioning)</description>
<enabled>false</enabled>
<latching>true</latching>
<annunciating>true</annunciating>
<guidance>
......@@ -181,26 +175,6 @@
<details>Disable the repeller bias in the FC ME OPI. In the 'repeller bias' section, set the high voltage = 0 and the current limit = 0 ASAP</details>
</guidance>
</pv>
<pv name="DTL-040:PBI-FC-001:Voltage-R">
<description>Voltage readback for the DTL4 FC (placeholder - disabled)</description>
<enabled>false</enabled>
<latching>true</latching>
<annunciating>true</annunciating>
<guidance>
<title>Overvoltage on the DTL4 FC</title>
<details>Disable the repeller bias in the FC ME OPI. In the 'repeller bias' section, set the high voltage = 0 and the current limit = 0 ASAP</details>
</guidance>
</pv>
<pv name="DTL-040:PBI-FC-001:HVCurrent-R">
<description>Current readback for the DTL4 FC (placeholder - disabled)</description>
<enabled>false</enabled>
<latching>true</latching>
<annunciating>true</annunciating>
<guidance>
<title>Overcurrent on the DTL4 FC</title>
<details>Disable the repeller bias in the FC ME OPI. In the 'repeller bias' section, set the high voltage = 0 and the current limit = 0 ASAP</details>
</guidance>
</pv>
</component>
</component>
</config>
This diff is collapsed.
......@@ -160,6 +160,11 @@
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
<pv name="Tgt-MRCS:Ctrl-PLC-001:1054_YSV_001_WearMon">
<description>YSV 001 Valve wear monitoring alarm</description>
<latching>false</latching>
<annunciating>false</annunciating>
</pv>
</component>
<component name="1078">
<pv name="Tgt-Resn1078:Proc-PIT-101:Overrange">
......