CAP-426: Added differential measurement support to LTC-2991

Added three new configuration parameters to AKI2CLTC2991Configure:

  • Value of V1,V2 and V3,V4 Control Register (Table 5 in docs)
  • Value of V5,V6 and V7,V8 Control Register (Table 6 in docs)
  • Value of PWM, Vcc, Tinternal Control Register (Table 7 in docs)

If not specified then 0 is used that also happens to be the hardware default so everything is backwards compatible.

Dear @hinkokocevar, could you please merge this?

Thanks!

Fixes #1 (closed)