Newer
Older
Jerzy Jamroz
committed
"id": 10,
],
"description":"Plasma production, magnetron allowed but no extraction HV"
Jerzy Jamroz
committed
"id": 20,
],
"description": "First beam through a particular section; non-damaging even in the case of total beam loss (even repeated); used to verify that machine configuration is not grossly incorrect"
Jerzy Jamroz
committed
"id": 30,
"events": [
"ION_ST",
"ION_END",
"DATA"
],
"description" : "Limited beam loading; used for fast scans to rapidly determine/verify RF setpoints"
},
Jerzy Jamroz
committed
"id": 40,
"events": [
"ION_ST",
"ION_END",
"DATA"
],
"description" : "To perform an initial RF test with a longer pulse"
},
Jerzy Jamroz
committed
"id": 50,
"events": [
"ION_ST",
"ION_END",
"DATA"
],
"description" : "To be used mostly for beam stability test"
},
Jerzy Jamroz
committed
"id": 60,
Jerzy Jamroz
committed
"description" : "Very short pulse planned to be used used during Normal Conducting Linac commissioning. It would allow installation of the rest of the Linac in parallel to Beam Commissioning."
Jerzy Jamroz
committed
"id": 70,
Jerzy Jamroz
committed
"description" : "Limited beam loading; used for fast scans to rapidly determine/verify RF setpoints and measure beam profiles with wire scanners"
Jerzy Jamroz
committed
"Slow Tuning": {
"id": 80,
"events": [
"ION_ST",
"ION_END",
"BPULSE_CM",
"BPULSE_ST",
"BPULSE_END",
"DATA"
Jerzy Jamroz
committed
],
"description" : "Largest charge per pulse that allow operation of invasive proton beam instrumentation devices like wire scanners; long enough beam pulses to diagnose and monitor RF feedback and the onset of beam loading; used to perform more precise single-pulse measurements"
Jerzy Jamroz
committed
"id": 90,
],
"description" : "Only used when machine reasonably tuned to the tuning dump or the target; slowly-increasing pulse lengths are used to tune RF feedforward, verify beam loading and Lorentz force detuning compensation, and tune for low beam losses. Iintermediate short pulses at 1Hz could be supplied to monitor stability between long pulses."
Jerzy Jamroz
committed
"id": 100,
"events": [
"ION_ST",
"ION_END",
"BPULSE_CM",
"BPULSE_ST",
"BPULSE_END",
"DATA"
],
"description" : "To be defined better once the exact requirements for the shielding verification (power, pulse length) are known."
Jerzy Jamroz
committed
"id": 110,
"events": [
"ION_ST",
"ION_END",
"BPULSE_CM",
"BPULSE_ST",
"BPULSE_END",
"DATA"
],
"description" : "Normal mode for NSS experiments during operation"
},
"Global": {
"pv": "PBMod"
}
},
"Destination": {
"None": {
"id": 0
},
Jerzy Jamroz
committed
"id": 10,
"type" : "Virtual destination for plasma conditioning",
"limits" : "Only for conditioning mode/0/0/0"
Jerzy Jamroz
committed
"id": 20,
Jerzy Jamroz
committed
"id": 30,
"type" : "Faraday Cup",
"limits" : "(1Hz, 50us)/(14Hz, 5us), 62.5 mA"
Jerzy Jamroz
committed
"id": 40,
"type" : "Faraday Cup",
"limits" : "(1Hz, 50us)/(14Hz, 5us), 62.5 mA"
Jerzy Jamroz
committed
"id": 50,
"type" : "Faraday Cup",
"limits" : "(1 Hz, 50us)/(14 Hz, 5us), 62.5 mA"
Jerzy Jamroz
committed
"id": 60,
"type" : "Beam Stop",
"limits" : "To be defined"
},
"MBL": {
Jerzy Jamroz
committed
"id": 70,
Jerzy Jamroz
committed
"id": 80,
Jerzy Jamroz
committed
"id": 90,
},
"Global": {
"pv": "PBDest"
}
},
"Target": {
"Global": {
"pv": "TgSeg"
}
}