First attempt to implement the blanking feature
The RF blanking feature will to the following steps:
- Increment the MMDly by RFBlankingDly (15ms)
- Increment the SCDly by RFBlankingDly (15ms)
What will result on all trigger be moved by a shift of RFBlankingDly.
When "Unblanking" there was included a feature to disable the pulsers for 71ms, this way we avoid triggers arriving in a interval faster than 14Hz.
Closes ICSHWI-17119
Edited by Gabriel Fedel